[vc_row][vc_column][spacing desktop_height=”50″ mobile_height=”20″ smobile_height=”20″][/vc_column][/vc_row][vc_row][vc_column][vc_empty_space][/vc_column][/vc_row][vc_row][vc_column][deeper_advance_tabs][deeper_advance_tab tab_title=”GE”][vc_row_inner][vc_column_inner width=”1/2″][vc_column_text]
Light Speed VCT 64 Slice
| Specification | Parameter |
|---|---|
| Gantry Aperture | 70 cm |
| Gantry Tilt | 30 – + |
| Scan Thickness | 0.65,1,25,2.5,5 mm |
| Scan Speed | 0.4 – 2 Sec |
| Scan KVP | 80, 100,120,140 |
| Scan mA | Upto 700 mA |
| Tube Capacity | 8 mhu |
| Tube Name | Performix Pro 100 |
| Detector Type | Solid State Array |
| Power Supply | 10 KVA |
| Scan FOV | 50cm |
| Dicom | YES |
| Recommended | Below 80 Cases |
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″][spacing desktop_height=”100″ mobile_height=”20″ smobile_height=”20″][imagescarousel images=”9529″ auto_scroll=”true” gap=”0″ show_arrows=”yes” arrow_position=”bottom” column=”1c” column2=”1c”][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][spacing desktop_height=”100″ mobile_height=”20″ smobile_height=”20″][imagescarousel images=”9530″ auto_scroll=”true” gap=”0″ show_arrows=”yes” arrow_position=”bottom” column=”1c” column2=”1c”][/vc_column_inner][vc_column_inner width=”1/2″][vc_column_text]
Light Speed VCT 16 Slice
| Specification | Parameter |
|---|---|
| Gantry Aperture | 70 cm |
| Gantry Tilt | 30 |
| Scan Thickness | .625, 1.25, 2.5 |
| Scan Speed | 3.75, 5, 7.5, 10 mm 0.5, 0.6, 0.7, 0.8, 0.9, 1, 2, 3 |
| Scan KVP | 80, 100,120,140 Kv |
| Scan mA | Upto 440 mA |
| Tube Capacity | 6.3 mhu |
| Detector Type | 16 X 912 ROWS |
| Scan FOV | 25, 50 |
| Dicom | In built |
| Recommended | Below 100 Cases |
[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][vc_column_text]
Light Speed Ultra 8 Slice
| Specification | Parameter |
|---|---|
| Gantry Aperture | 70 cm |
| Gantry Tilt | 30 |
| Scan Thickness | .625, 1.25, 2.5, 3.75, 5, 7.5 MM |
| Scan Speed | 0.5, 0.6, 0.7, 0.8, 0.9, 1, 2, 3 |
| Scan KVP | 80, 100, 120,140 Kv |
| Scan mA | Upto 440 mA |
| Tube Capacity | 6.3 mhu |
| Detector Type | 8 X 912 ROWS |
| Scan FOV | 25, 50 |
| Dicom | In built |
| Recommended | Below 75 Cases |
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″][spacing desktop_height=”100″ mobile_height=”20″ smobile_height=”20″][imagescarousel images=”9531″ auto_scroll=”true” gap=”0″ show_arrows=”yes” arrow_position=”bottom” column=”1c” column2=”1c”][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][spacing desktop_height=”100″ mobile_height=”20″ smobile_height=”20″][imagescarousel images=”9532″ auto_scroll=”true” gap=”0″ show_arrows=”yes” arrow_position=”bottom” column=”1c” column2=”1c”][/vc_column_inner][vc_column_inner width=”1/2″][vc_column_text]
Light Speed QXI 4 Slice Spiral
| Specification | Parameter |
|---|---|
| Gantry Aperture | 70 cm |
| Gantry Tilt | 30 |
| Scan Thickness | 0.5, 0.6, 0.7, 0.8, 0.9, 1, 2, 3, 4 |
| Scan Speed | 0.63, 1.25, 2.5, 3.75, 7.5, 10 Sec |
| Scan KVP | 80, 100, 120,140 Kv |
| Scan mA | Upto 440 mA |
| Tube Capacity | 6.3 mhu |
| Detector Type | Four rows of HR detectors |
| Scan FOV | 18, 25, 42, 50 cm |
| Dicom | In built |
| Recommended | Below 50 Cases |
[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][vc_column_text]
Hi Speed NXI-NXI Pro – CT/e 2 Slice Spiral
| Specification | Parameter |
|---|---|
| Gantry Aperture | 70 cm |
| Gantry Tilt | 30 |
| Scan Thickness | 0.5, 1, 2, 3, 4, 5, 6, 7, 10 mm |
| Scan Speed | 0.7, 1, 1.5, 2, 3 Sec |
| Scan KVP | 80, 120,140 Kv |
| Scan mA | Upto 440 mA |
| Tube Capacity | 6.3 / 3.5 / 2.0 Mhu |
| Detector Type | Two rows of HR |
| Scan FOV | 18, 25, 35, 50 cm |
| Dicom | In built |
| Recommended | Below 40 Cases |
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″][spacing desktop_height=”100″ mobile_height=”20″ smobile_height=”20″][imagescarousel images=”9533″ auto_scroll=”true” gap=”0″ show_arrows=”yes” arrow_position=”bottom” column=”1c” column2=”1c”][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][spacing desktop_height=”100″ mobile_height=”20″ smobile_height=”20″][imagescarousel images=”9534″ auto_scroll=”true” gap=”0″ show_arrows=”yes” arrow_position=”bottom” column=”1c” column2=”1c”][/vc_column_inner][vc_column_inner width=”1/2″][vc_column_text]
HiSpeed LXI – DXI FXI – ZXI – CT/e Fast Single Slice
| Specification | Parameter |
|---|---|
| Gantry Aperture | 65 / 70 cm |
| Gantry Tilt | 30 |
| Scan Thickness | 01,2,3,5,7,10 mm |
| Scan Speed | 0.8, 1,1.5,2,3 sec |
| Scan KVP | 80, 120,140 Kv |
| Scan mA | upto 350 mA |
| Tube Capacity | 2 / 3.5 / 6.3 mhu |
| Detector Type | Solid state detector |
| Scan FOV | 18, 25, 42, 50 cm |
| Dicom | In built |
| Recommended | Below 30 Cases |
[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][vc_column_text]
Prospeed Single Slice Spiral C T
| Specification | Parameter |
|---|---|
| Gantry Aperture | 68 cm |
| Gantry Tilt | 25 |
| Scan Thickness | 1,2,3,5,7,10 mm |
| Scan Speed | 1.5,2,3 sec |
| Scan KVP | 80, 120,140 Kv |
| Scan mA | upto 350 mA |
| Tube Capacity | 3.5 mhu |
| Detector Type | Soild State / xenon |
| Scan FOV | 25,35,42,50 cm |
| Dicom | Optional |
| Recommended | Below 25 Cases |
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″][spacing desktop_height=”100″ mobile_height=”20″ smobile_height=”20″][imagescarousel images=”9535″ auto_scroll=”true” gap=”0″ show_arrows=”yes” arrow_position=”bottom” column=”1c” column2=”1c”][/vc_column_inner][/vc_row_inner][/deeper_advance_tab][deeper_advance_tab tab_title=”Siemens”][vc_row_inner][vc_column_inner width=”1/2″][vc_column_text]
SIEMENS Somatom Sensation 64 Slice
| Specification | Parameter |
|---|---|
| Gantry Aperture | 78 cm |
| Gantry Tilt | 30 -+ |
| Scan Thickness | 0.1- 10 mm |
| Scan Speed | 0.33 -1.0 Sec |
| Scan KVP | 80, 100,120,140 |
| Scan mA | Upto 500 mA |
| Tube Capacity | 7.3 mhu |
| Tube Name | STARATON |
| Detector Type | multislice UFC |
| Scan FOV | 78 cm |
| Dicom | YES |
| Recommended | Below 80 Cases |
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″][spacing desktop_height=”100″ mobile_height=”20″ smobile_height=”20″][imagescarousel images=”9537″ auto_scroll=”true” gap=”0″ show_arrows=”yes” arrow_position=”bottom” column=”1c” column2=”1c”][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][spacing desktop_height=”100″ mobile_height=”20″ smobile_height=”20″][imagescarousel images=”9538″ auto_scroll=”true” gap=”0″ show_arrows=”yes” arrow_position=”bottom” column=”1c” column2=”1c”][/vc_column_inner][vc_column_inner width=”1/2″][vc_column_text]
SIEMENS Somatom Sensation 16 Slice
| Specification | Parameter |
|---|---|
| Gantry Aperture | 78 cm |
| Gantry Tilt | 30 -+ |
| Scan Thickness | 0.1- 10 mm |
| Scan Speed | 0.33 -1.0 Sec |
| Scan KVP | 80, 100,120,140 |
| Scan mA | Upto 500 mA |
| Tube Capacity | 5.3 MHU |
| Tube Name | AKRON Q / STARATION |
| Detector Type | multislice UFC |
| Scan FOV | 70 cm |
| Dicom | YES |
| Recommended | Below 65 Cases |
[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][vc_column_text]
SIEMENS Somatom Sensation 4 Slice
| Specification | Parameter |
|---|---|
| Gantry Aperture | 78 cm |
| Gantry Tilt | 30 -+ |
| Scan Thickness | 0.1- 10 mm |
| Scan Speed | 0.5,1.0s,1.5 Sec |
| Scan KVP | 80, 110, 130 |
| Scan mA | Upto 500 mA |
| Tube Capacity | 5.3 mhu |
| Tube Name | AKRON B |
| Detector Type | UFC |
| Scan FOV | 70 cm |
| Dicom | YES |
| Recommended | Below 50 Cases |
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″][spacing desktop_height=”100″ mobile_height=”20″ smobile_height=”20″][imagescarousel images=”9539″ auto_scroll=”true” gap=”0″ show_arrows=”yes” arrow_position=”bottom” column=”1c” column2=”1c”][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][spacing desktop_height=”100″ mobile_height=”20″ smobile_height=”20″][imagescarousel images=”9540″ auto_scroll=”true” gap=”0″ show_arrows=”yes” arrow_position=”bottom” column=”1c” column2=”1c”][/vc_column_inner][vc_column_inner width=”1/2″][vc_column_text]
SIEMENS Emotion Duo 2 Slice
| Specification | Parameter |
|---|---|
| Gantry Aperture | 78 cm |
| Gantry Tilt | 30 -+ |
| Scan Thickness | 0.1- 10 mm |
| Scan Speed | 0.5,1.0s,1.5 Sec |
| Scan KVP | 80, 110, 130 |
| Scan mA | Upto 240 mA |
| Tube Capacity | 3.5 MHU |
| Tube Name | DURA 352MV |
| Detector Type | DURA 352MV |
| Scan FOV | 70 cm |
| Dicom | YES |
| Recommended | Below 40 Cases |
[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][vc_column_text]
SIEMENS Somatom Sprit 2 Slice
| Specification | Parameter |
|---|---|
| Gantry Aperture | 69 cm |
| Gantry Tilt | 25, 30 – + |
| Scan Thickness | 0.1- 10 mm |
| Scan Speed | 0.8,1.0,1.5 Sec |
| Scan KVP | 80, 120, 140 |
| Scan mA | Upto 240 mA |
| Tube Capacity | 2.0 MHU |
| Tube Name | DURA 187 MV |
| Detector Type | UFC |
| Scan FOV | 69 cm |
| Dicom | YES |
| Recommended | Below 40 Cases |
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″][spacing desktop_height=”100″ mobile_height=”20″ smobile_height=”20″][imagescarousel images=”9542″ auto_scroll=”true” gap=”0″ show_arrows=”yes” arrow_position=”bottom” column=”1c” column2=”1c”][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][spacing desktop_height=”100″ mobile_height=”20″ smobile_height=”20″][imagescarousel images=”9541″ auto_scroll=”true” gap=”0″ show_arrows=”yes” arrow_position=”bottom” column=”1c” column2=”1c”][/vc_column_inner][vc_column_inner width=”1/2″][vc_column_text]
SIEMENS Esprit 2 Slice
| Specification | Parameter |
|---|---|
| Gantry Aperture | 65 cm |
| Gantry Tilt | 25 – + |
| Scan Thickness | 1,3,5,8,10 mm |
| Scan Speed | 1.0,1.5,2.0 Sec/td> |
| Scan KVP | 80, 110, 130 |
| Scan mA | Upto 160 mA |
| Tube Capacity | 2.0 MHU |
| Tube Name | DURA 187 MV |
| Detector Type | UFC |
| Scan FOV | 65 cm |
| Dicom | YES |
| Recommended | Below 30 Cases |
[/vc_column_text][/vc_column_inner][/vc_row_inner][/deeper_advance_tab][/deeper_advance_tabs][/vc_column][/vc_row][vc_row][vc_column][spacing desktop_height=”30″ mobile_height=”20″ smobile_height=”20″][spacing desktop_height=”30″ mobile_height=”20″ smobile_height=”20″][/vc_column][/vc_row]